Network description
The network is composed of iLive nodes.
Network topology is a star topology.
The communication technologies is ZigBeePro
There are several deployments in Montoldre (IRSTEA) and in ISIMA (LIMOS).
Could we have more information about these deployments What are the date and the duration of this deployment.
The software used are:
- The end-device uses ATMEL and LIMOS firmware.
- The local server or edge router is based on LINUX, ATMEL and LIMOS firmware.
- The remote server is a HTTP server.
Network deployment of iLive in 2018 at Montoldre
- Node 62-BE-6D-14-00-00-01-00 tensiometre 22, 23, 24 on plot Pal 2_3_4
- Node 91-BC-6D-14-00-00-01-00 tensiometre 1, 2, 3 close to the coordinateur node. (pelouse pres du Cemib)
Network deployment of iLive at Montoldre from 2015 to 2017
- Node 28-92-6D-14-00-00-01-00 tensiometre 19-20-21 on plot Pal8
Watermark1=tensiomètre19; Watermark2=tensiomètre20; Watermark3=tensiomètre21;
- Node 70-97-6D-14-00-00-01-00 Nœud pour test de portée, tensiomètres 7, 8, 9 on plot Pal 14C
Watermark1=tensiomètre7; Watermark2=tensiomètre8; Watermark3=tensiomètre9;
- Node 72-7E-6D-14-00-00-01-00 Nœud de test distance du coordinateur : environ 20 m, puis tensiomètres 1,2,3 sur parcelle Pal 14A
Watermark1=tensiomètre1; Watermark2=tensiomètre2; Watermark3=tensiomètre3;
- Node 73-C1-6D-14-00-00-01-00 Nœud « Coordinateur » en intérieur bâtiment
- Node B3-C0-6D-14-00-00-01-00 tensiometre 10,11,12 in the plot Pal5-6-7
les tensiomètres 13, 14, 15 n'ont jamais été connectés mais sont voisins du Node B3-C0-6D-14-00-00-01-00 Watermark1=tensiomètre10; Watermark2=tensiomètre11; Watermark3=tensiomètre12;
- Node E7-A4-6D-14-00-00-01-00 Node for the test of range, soil sensors 4,5,6 in the plot Pal 14C
Watermark1=tensiomètre4; Watermark2=tensiomètre5; Watermark3=tensiomètre6;
Network deployment at LIMOS from date to 2014
The network called iLive 2012 is composed of 10 nodes:
- Node 28-92-6D-14-00-00-01-00
- Node 62-BE-6D-14-00-00-01-00
- Node 70-97-6D-14-00-00-01-00
- Node 72-7E-6D-14-00-00-01-00
- Node 73-C1-6D-14-00-00-01-00
- Node 85-9A-6D-14-00-00-01-00
- Node 91-BC-6D-14-00-00-01-00
- Node B3-C0-6D-14-00-00-01-00
- Node BA-9E-6E-14-00-00-01-00
- Node E7-A4-6D-14-00-00-01-00
RCSF Database description
http://cfs-vcapti.clermont.cemagref.fr/phpmyadmin/. The database is composed of two tables:
- network_table : stockage de l'organisation du réseau
- sensor_table : stockage des données collectées
The data before 2014 is just test data for network deployment. To have useful data reused the one from 20 May to 17 Septembre of 2014, 2015 voire 2016. the date of the database dump is <2017-07-20 14:00>
network_table
myNodeID
myParentID
packetTime
dbTime
messageType
nodeType
extAddr
...
softVersion
sensor_table
myNodeID
myParentID
packetTime
dbTime
lqi
rssi
battery
temperature
humidity
light
decagon n
Decagon sensors are not used at Montoldre
watermark n
200 value mean there is a problem.
- watermark1 description This sensor is deployed at 10 cm depth in the soil
- watermark2 description This sensor is deployed at 20 cm depth in the soil
- watermark3 description This sensor is deployed at 30 cm depth in the soil
- watermark4 description: This watermark is never used.
softVersion
packetTimeMS